In most of the systems we test, the worst outcome is a data breach. In clinical AI it is a wrong answer that a clinician acts on. That inverts the usual priority order: integrity and accountability come first, confidentiality second — and confidentiality is already a high bar, because health data is sensitive personal data under India’s DPDP Act and under every other regime you will be asked about.
Integrity: the attacks that change the output
- Input tampering in transit. A DICOM study or lab panel altered between the modality and the inference service changes the diagnosis with no interaction with the model at all. We test whether studies are integrity-protected end to end or merely encrypted in transit on one hop.
- Adversarial perturbation of imaging inputs. Imperceptible changes that flip a classifier are a documented research result, and the realistic attack path is a compromised PACS or an upload route, not a man in the middle.
- Retrieval poisoning. Clinical assistants that cite guidelines from a retrieval corpus will cite a poisoned corpus just as confidently. If clinicians can contribute documents, or if the corpus syncs from an external source, that is an ingestion route and it needs provenance and review.
- Prompt injection through patient-supplied text. Intake forms, symptom descriptions and uploaded prior reports all land in the context window. We plant instructions in a free-text symptom field and see whether they reach the summary a clinician reads.
- Silent model substitution. Can anyone with pipeline access swap the served model or its weights without a record? This is where a software supply chain review belongs in a clinical stack.
Accountability: what the record has to show
After an adverse event, somebody will reconstruct the decision. The system has to be able to answer: which model version produced this output, on which inputs, at what time, which clinician saw it, what the displayed confidence was, and whether they overrode it. We test this as a capability, by picking a historical case and attempting the reconstruction from logs alone.
- Model and prompt version recorded with every inference, immutably.
- Inputs hashed and retained so the exact input can be proven, not approximated.
- Clinician identity on view and on override, with no shared accounts — shared clinical logins are still the most common finding in Indian healthtech deployments we review.
- Logs that the application cannot rewrite, held outside the application’s own credentials.
Confidentiality, under Indian law and the ones buyers import
Health data is sensitive by nature and DPDP treats processing of it with correspondingly tighter expectations on purpose limitation, consent and breach notification; hospital procurement will additionally ask about ABDM alignment where the deployment touches health IDs, and multinational customers will apply HIPAA-shaped questions whether or not HIPAA applies. The practical test questions are the same in all three:
- Does patient data leave the deployment, and for what — inference, logging, evaluation, or training? Training on patient data without a lawful basis is the finding that stops a hospital deal.
- Is the model provider contracted as a processor, with training excluded and retention defined, and is that list of sub-processors something you can produce on request?
- Can one clinician, department or facility reach another’s records through the AI feature when they cannot through the EMR? Retrieval layers routinely bypass the EMR’s own access model.
- Do prompts and completions containing patient data sit in observability tooling with wide internal access? This is the most common accidental disclosure path we find.
- Does erasure propagate to embeddings, caches, evaluation datasets and backups, within a period you can state?
Safety behaviour we test for explicitly
- Refusal and escalation on out-of-distribution input: an image from the wrong modality, an adult protocol applied to a paediatric case, a question outside the validated indication.
- Confidence that degrades honestly rather than presenting a guess in the same register as a certainty.
- Dosage, units and laterality in generated text, where an error is both easy for a model to make and easy for a reader to miss.
- A clear, non-dismissable statement of the system’s role as decision support, present in the output a clinician reads rather than only in onboarding material.
Where to start
Take one inference from last month and try to reconstruct it completely: inputs, model version, output, who saw it, what they did. If you cannot, that gap is the first finding, and it is the one that matters most when something goes wrong.